MicroAire PAL-650 Power-Assisted Liposuction Guide

Why the MicroAire PAL-650 Remains a Leading Power-Assisted Liposuction System

When discussing power-assisted liposuction technology, few systems are as recognizable as the MicroAire PAL-650. For years, surgeons and facilities performing aesthetic body contouring procedures have relied on the combination of the PAL-650 handpiece and the MicroAire 5020 Electric Instrument Console to create an integrated power-assisted liposuction platform.

The MicroAire PAL System is indicated for the removal of tissue and fluid from the body during general surgical procedures, including suction lipoplasty for aesthetic body contouring. According to the manufacturer, the system consists of the PAL-650 Electric Handpiece, the 5020 Electric Instrument Console, the 5006-PAL instrument cable, aspiration tubing, and compatible cannulas.²

For facilities seeking a complete system, Simon Medical, Inc. currently offers the complete package here:

the MicroAire PAL-650 system

What Is Included in Our Sale?

Unlike listings that include only the console or handpiece, our package includes a complete system configuration designed to help facilities obtain the major components required for operation.

Included with this sale:

  • MicroAire 5020 Power Assisted Liposuction Console
  • MicroAire PAL-650 Power-Assisted Liposuction Handpiece
  • MicroAire 5006-PALE Liposuction Cable
  • MicroAire PAL-402LS, 4 mm, 22 cm, Tri-Port II Cannula
  • MicroAire PAL-402LL, 4 mm, 30 cm, Tri-Port II Cannula
  • MicroAire PAL-405LL, 4 mm, 30 cm, Double Mercedes Cannula
  • MicroAire PAL-406LL, 4 mm, 30 cm, Mirrored Tri-Port II Cannula
  • MicroAire PAL-302LS, 3 mm, 22 cm, Tri-Port II Cannula
  • MicroAire PAL-302LL, 3 mm, 30 cm, Tri-Port II Cannula
  • MicroAire PAL-304LS, 3 mm, 22 cm, Mercedes Cannula
  • MicroAire PAL-304LL, 3 mm, 30 cm, Mercedes Cannula
  • MicroAire PAL-240LS, 2.4 mm, 22 cm, Single-Port Cannula
  • MicroAire PAL-240SS, 2.4 mm, 22 cm, Single-Port Cannula
  • MicroAire PAL-500 Sterilization Tray
  • 90-Day Warranty
  • Overnight Shipping Included

View current availability here:

the MicroAire PAL-650 system

Understanding the PAL-650 Handpiece

The PAL-650 is a powered surgical instrument that vibrates a cannula used during aesthetic body contouring procedures. The handpiece is powered by the MicroAire 5020 Electric Instrument Console and connected using the 5006-PAL cable.²

The manufacturer notes that the user can place the PAL-650 in either ON or STAND-BY mode through the slider switch located directly on the instrument. The handpiece speed can be adjusted during operation while maximum speed is controlled through the console.²

Because the PAL-650, cable, and console function together as an integrated system, the manufacturer recommends evaluating all three components together if troubleshooting becomes necessary.²

The Importance of the MicroAire 5020 Console

The 5020 console is the heart of the PAL platform. According to the Instructions for Use, the console provides isolated control signals to the PAL-650 handpiece through the instrument cable.²

The console is responsible for powering the handpiece and coordinating system operation. This integrated design has helped make the PAL platform one of the most widely recognized power-assisted liposuction systems available.

Facilities looking for a complete PAL setup often prefer a system that includes both the PAL-650 handpiece and the 5020 console together rather than purchasing components separately.

Current inventory may be viewed here:

the MicroAire PAL-650 system

Cannula Options Included

One major advantage of this package is the inclusion of multiple cannula styles and sizes.

The included Tri-Port II cannulas provide facilities with several sizing options. Multiple 3 mm and 4 mm configurations are included, along with Mercedes-style cannulas and smaller 2.4 mm single-port cannulas.

Having a variety of cannula options available allows facilities to maintain flexibility when configuring the PAL system.

The manufacturer's documentation notes that the PAL system supports multiple cannula styles, including both single-use and multi-use configurations.²

System Setup

The Instructions for Use outline a straightforward setup process.

The manufacturer recommends inspecting the handpiece, console, cable, and cannulas before use. Sterile disposable items should also be inspected to verify packaging integrity. The cable connects the console to the PAL-650 handpiece, while aspiration tubing connects the cannula to a collection canister.²

Once assembled, the thumb-throttle can be moved from STAND-BY to ON, allowing the user to control powered reciprocation during operation.²

Cleaning and Sterilization

Proper cleaning and sterilization are essential for maintaining system performance.

The manufacturer specifically instructs users not to immerse the PAL handpiece or cable. Multi-use components must be sterilized before use, and cleaning should begin within 30 minutes whenever possible.²

Additional manufacturer recommendations include:

  • Use mild pH cleaning solutions.
  • Avoid chlorine-containing cleaning agents.
  • Inspect components for wear and contamination.
  • Follow validated steam sterilization procedures.²

The included PAL-500 sterilization tray helps organize system components during processing and storage.

Facilities seeking a complete PAL package that includes the sterilization tray can view the system here:

the MicroAire PAL-650 system

Preventative Maintenance

According to MicroAire, routine inspection and testing should be performed in accordance with facility biomedical engineering policies. Due to repeated surgical use and reprocessing cycles, the manufacturer recommends annual inspection and service of the PAL-650 handpiece, cable, and 5020 console.²

The Instructions for Use specifically caution against lubricating the PAL handpiece because lubrication may damage the internal motor mechanism.²

Proper preventative maintenance helps maximize system longevity and performance.

Troubleshooting Common Issues

The manufacturer identifies several common troubleshooting scenarios:

  • Difficulty attaching the cable
  • Bent connector pins
  • Corroded contacts
  • Startup issues
  • Console communication concerns²

The IFU emphasizes proper alignment of the white and red connector indicators and cautions users against forcing cable connections because connector damage may occur.²

Because the PAL-650, cable, and console function as a complete system, the manufacturer recommends evaluating all components together during troubleshooting.²

Why Buy from Simon Medical, Inc.?

At Simon Medical, Inc., we understand that facilities need equipment that arrives quickly and is ready for inspection upon receipt.

This system includes:

  • Complete PAL-650 System Configuration
  • Multiple Cannula Options
  • PAL-500 Sterilization Tray
  • 90-Day Warranty
  • Overnight Shipping Included

We are also happy to provide additional photographs, answer configuration questions, and provide a live video demonstration before purchase.

To learn more about the complete MicroAire PAL-650 Power-Assisted Liposuction Set with MicroAire 5020 Power Console, visit:

the MicroAire PAL-650 system

References

  1. Simon Medical, Inc. MicroAire PAL-650 Power-Assisted Liposuction Set with MicroAire 5020 Power Console. Accessed June 7, 2026.
  2. MicroAire Surgical Instruments LLC. PAL-650 MicroAire PAL System Instructions for Use. Revision S. December 2020.

Join our mailing list

ENT and Spine equipment news, restock alerts, and offers from Simon Medical.

Scroll to Top